Wastewater Calculator
Runs the everyday process-control numbers for an activated sludge plant, from the primary clarifier through the aeration tank to the secondary clarifier. Pick what you need: the F/M ratio on a BOD or COD basis (from flow and concentration or a known loading, with MLVSS from concentration and tank volume or as a mass), hydraulic retention time, mean cell residence time with or without clarifier solids, sludge age, the sludge volume index from a 30-minute settleometer reading, removal efficiency, or clarifier surface overflow rate. US units use the operator 8.34 lb factor; metric units give kilograms directly.
- Flows are daily averages and concentrations are representative composite results for the same period.
- US gallons are used for all gallon units, and 8.34 lb per million gallons per mg/L is applied to US flows and volumes as in operator practice.
- MLSS is taken as uniform through the aeration tank and clarifiers when they are added to the MCRT inventory.
- This is a process-control and exam-practice aid; plant decisions and permit reporting must follow your plant's procedures and approved methods.
Formula
- 8.34 is the weight in pounds of 1 mg/L in 1 million US gallons (8.345 rounded), the factor used on US operator formula sheets. It is applied whenever a flow or volume is in US units; metric units use kg = m³ × mg/L ÷ 1,000 exactly, so a mixed US/metric entry can differ by about 0.06%.
- The F/M ratio's food is the BOD (or COD) leaving the primary clarifier: influent concentration minus what primary treatment removed, times the flow. The microorganisms are the MLVSS in the aeration tank, so F/M is in lb per day per lb (or kg per day per kg), i.e. per day.
- MCRT counts all the solids in the activated sludge process and divides by the solids that leave it each day in the secondary effluent and the waste sludge. Leave the clarifier volume blank to count only the aeration tank, as on many state formula sheets.
- Sludge age uses only the aeration tank and divides by the suspended solids arriving from the primary clarifier each day, so it is a loading-based age rather than a wasting-based one like MCRT.
- SVI is the volume in millilitres that 1 g of mixed liquor solids occupies after 30 minutes of settling. With a 1 L cylinder the settled reading in mL is already mL/L; other cylinder sizes are scaled to 1 L.
- Surface overflow rate uses the full water surface (π × diameter² ÷ 4 for a circular clarifier); formula sheets that use 0.785 × D² give the same answer to three figures.
F/M ratio of a 3 MGD activated sludge plant
- What do you want to calculate?: fm
- Concentration unit: mgL
- Flow unit: mgd
- Tank volume unit: MG
- Organic load measured as: bod
- What do you know about the food supply?: split
- Primary effluent flow to aeration: 3 MGD
- Average untreated influent BOD: 220 mg/L
- BOD removed by primary treatment: 70 mg/L
- BOD entering the aeration tank: 150 mg/L
- Average untreated influent COD: 450 mg/L
- COD removed by primary treatment: 140 mg/L
- COD entering the aeration tank: 310 mg/L
- Loading unit: lb
- BOD loading to aeration: 3753 lb/day
- COD loading to aeration: 7756 lb/day
- Is the aeration tank volume known?: conc
- Aeration tank volume: 0.75 MG
- MLVSS concentration: 2000 mg/L
- Mass unit: lb
- MLVSS under aeration: 12510 lb
- Aeration tank volume: 0.75 MG
- Flow through the tank (primary effluent): 3 MGD
- MLSS concentration: 2500 mg/L
- Primary effluent suspended solids: 80 mg/L
- Secondary clarifier volume (optional): 0.25 MG
- Secondary effluent flow: 2.9 MGD
- Secondary effluent TSS: 12 mg/L
- Waste activated sludge (WAS) flow: 0.06 MGD
- WAS suspended solids: 8000 mg/L
- Settled sludge after 30 minutes: 300 mL
- Sample volume in the cylinder: 1000 mL
- Influent concentration: 220 mg/L
- Effluent concentration: 15 mg/L
- Flow (optional): MGD
- Flow to the clarifiers: 3 MGD
- Clarifier shape: circle
- Length unit: ft
- Diameter: 80 ft
- Length: 100 ft
- Width: 25 ft
- Number of clarifiers in service: 1
Raw sewage at 220 mg/L BOD loses 70 mg/L in the primary clarifier, so 150 mg/L enters aeration. At 3 MGD the BOD loading is 3 × 150 × 8.34 = 3,753 lb/day. The 0.75 MG aeration tank holds 2,000 mg/L MLVSS, or 0.75 × 2,000 × 8.34 = 12,510 lb. F/M = 3,753 ÷ 12,510 = 0.300 lb BOD per day per lb MLVSS.