Vapor Pressure Deficit (VPD) Calculator

Air
°C
Measured in the shade near the canopy. Not needed for dew point mode when the leaf temperature is known.
%
Leaf
°C
From an infrared thermometer pointed at the canopy; usually a little below air temperature in a well-watered crop.
Biology Updated 5 Nov 2026

Works out the vapor pressure deficit (VPD) that drives transpiration in a greenhouse, grow tent or field crop: the gap between the water vapor pressure inside the leaf, taken as saturated at leaf temperature, and the vapor pressure of the surrounding air. Describe the air with relative humidity and air temperature, with a dew point reading, or with dry- and wet-bulb psychrometer temperatures. Add the canopy temperature from an infrared thermometer for leaf VPD, or leave it out to get the VPD of the air alone. Results come in kPa, mbar or psi, with the dew point and relative humidity that match your readings.

  • The air inside the leaf is saturated at leaf temperature, and vapor pressure over liquid water is used even below 0 °C (no ice correction).
  • Readings are taken at the same time and place, near the canopy. A single reading gives the VPD at that moment, not a daily average.
  • Ideal VPD ranges depend on the crop, growth stage and light level; the calculator reports the deficit but does not judge whether it suits a particular crop.

Formula

VPD = e°(T_leaf) − e_a, with the Tetens equation e°(T) = 0.61078 × exp[17.27 × T ÷ (T + 237.3)] kPa (T in °C). The actual vapor pressure e_a = e°(T_air) × RH ÷ 100, or e°(T_dew), or e°(T_wet) − a_psy × P × (T_air − T_wet).
  • The air inside the leaf is taken as saturated, so the leaf vapor pressure is simply e°(T) at leaf temperature. Without a leaf reading, the leaf is assumed to be at air temperature and the result is the VPD of the air: e°(T_air) × (1 − RH/100).
  • With a dew point, e_a = e°(T_dew), because air cooled to its dew point is saturated without its moisture content changing. The air temperature is then only needed when the leaf temperature is unknown.
  • With a psychrometer, e_a = e°(T_wet) − a_psy × P × (T_dry − T_wet) (FAO-56 eq. 15–16), where a_psy is 0.000662 °C⁻¹ for an aspirated instrument, 0.000800 for natural ventilation and 0.001200 for an indoor, non-ventilated one, and P is the atmospheric pressure in kPa.
  • The Tetens equation is accurate to about 0.1% between 0 and 50 °C; inputs from −50 to 60 °C are accepted. 1 kPa = 10 mbar (hPa) = 0.145038 psi. Vapor pressures are shown to 3 decimals in kPa, 2 in mbar and 4 in psi.
  • Dew point and relative humidity outputs come from the same Tetens equation solved backwards, so they stay consistent with the VPD shown.

Greenhouse at 22 °C and 55% RH with a 20 °C canopy

Inputs
  • Do you know the canopy (leaf) temperature?: yes
  • Describe the air with: rh
  • Temperature unit: C
  • Pressure unit: kPa
  • Air temperature (dry bulb): 22 °C
  • Relative humidity: 55 %
  • Dew point: 12 °C
  • Wet-bulb temperature: 16 °C
  • Atmospheric pressure: 101.3 kPa
  • Psychrometer type: aspirated
  • Leaf (canopy) temperature: 20 °C

The leaf at 20 °C holds saturated vapor at e°(20) = 0.61078 × exp(17.27 × 20 ÷ 257.3) = 2.338 kPa. The air at 22 °C could hold e°(22) = 2.644 kPa but is only 55% saturated, so its vapor pressure is 2.644 × 0.55 = 1.454 kPa. The leaf VPD is 2.338 − 1.454 = 0.884 kPa (8.84 mbar), and the air's dew point is 12.5 °C.

Sources & references

Frequently asked questions

What is vapor pressure deficit?
It is how far the air is from being saturated, expressed as a pressure. For plants, VPD compares the saturated air inside the leaf with the surrounding air: the bigger the gap, the faster water evaporates through the stomata. Unlike relative humidity, it accounts for temperature, so 60% RH at 35 °C (VPD 2.25 kPa) is far more drying than 60% RH at 18 °C (VPD 0.83 kPa).
What is the difference between leaf VPD and air VPD?
Air VPD assumes the leaf is at air temperature. Leaf VPD uses the measured canopy temperature, which is usually a degree or two cooler than the air in a transpiring crop and warmer under strong light. At 22 °C and 55% RH the air VPD is 1.190 kPa, but a 20 °C canopy sees only 0.884 kPa.
How do I calculate VPD from relative humidity?
Find the saturation vapor pressure at the air temperature with the Tetens equation, 0.61078 × exp[17.27T ÷ (T + 237.3)], then multiply by (1 − RH/100). At 25 °C, e° = 3.168 kPa, so at 70% RH the air VPD is 3.168 × 0.30 = 0.950 kPa.
Why use dew point instead of relative humidity?
The dew point fixes the actual vapor pressure of the air on its own, while relative humidity changes whenever the temperature does even if no water is added or removed. Climate controllers can therefore hold VPD by controlling one value, the dew point, against the measured leaf temperature.
What does a negative VPD mean?
The leaf is colder than the dew point of the air, so instead of losing water it collects condensation. Wet leaves for long periods favour fungal diseases such as botrytis and mildew, which is why growers raise heating or ventilation when the canopy approaches the dew point.