CO₂ Grow Room Calculator

Grow room dimensions
m
m
m
CO₂ levels
ppm
Measured level in the room; outdoor air is about 420 ppm.
ppm
Most crops respond up to 1,000–1,500 ppm.
CO₂ tank
min
Leakage (optional)
per hour
How many times per hour the room's air is replaced by outside air through leaks or ventilation. Leave blank for a sealed room.
Biology Updated 5 Nov 2026

Works out how much carbon dioxide to release into a grow room, grow tent or small greenhouse to lift it from the current concentration to a target level such as 1,200–1,500 ppm. Enter the room's width, length and height (or its volume) in metric or imperial units and the two CO₂ readings in ppm to get the gas volume in liters, cubic meters and cubic feet, plus its mass from the density of CO₂. Give the time the tank valve stays open to get the regulator flow rate, or give the flow rate to get the time. An optional air-change rate estimates the extra flow needed to hold the target against leakage, and the result flags targets above the 5,000 ppm workplace exposure limit.

  • The room is sealed while CO₂ is released and the air is well mixed; plant uptake during the release is ignored.
  • Concentrations are ppm by volume; gas volumes and the 1.84 kg/m³ density refer to about 20 °C and 1 atm.
  • Safety: 5,000 ppm is the OSHA PEL and NIOSH REL 8-hour exposure limit. Ventilate before entering an enriched room and use a CO₂ monitor; this tool does not replace one.
  • The 1,500 ppm plant warning is a general guide; tolerance differs between crops.

Formula

CO₂ needed = V_room × (CO₂ target − CO₂ current) ÷ 1,000,000; flow rate = CO₂ needed ÷ time; time = CO₂ needed ÷ flow rate; mass = CO₂ needed × 1.84 kg/m³
  • ppm means parts per million by volume, so raising a room by 1,000 ppm needs 1,000 ÷ 1,000,000 = 0.1% of the room volume as pure CO₂. The CO₂ volume comes out in the same unit as the room volume.
  • V_room = width × length × height. Feet, inches and centimeters are converted to meters first; 1 ft³ = 0.0283168 m³ and 1 m³ = 1,000 L.
  • Mass uses a CO₂ gas density of 1.84 kg/m³ at 20 °C and 1 atm, the same as Oklahoma State University's figure of 8.7 ft³ per pound. The density is about 1.98 kg/m³ at 0 °C, so a cold room needs about 7% more mass for the same volume.
  • The make-up flow assumes outside air enters at the current CO₂ level and the room is well mixed: extra CO₂ per hour = V_room × air changes per hour × (target − current) ÷ 1,000,000.
  • Rounding: liters and flow in L/min to 2 decimals, m³ to 4 decimals, ft³ to 3 decimals, grams to 1 decimal.

2 m × 2 m × 2.5 m grow room from 420 to 1,500 ppm in 10 minutes

Inputs
  • Room size from: dims
  • Width: 2 m
  • Length: 2 m
  • Height: 2.5 m
  • Length unit: m
  • Room volume: 10 m³
  • Volume unit: m3
  • Current CO₂: 420 ppm
  • Target CO₂: 1500 ppm
  • Calculate: flow
  • Time the valve is open: 10 min
  • Time unit: min
  • CO₂ flow rate: 1.08 L/min
  • Flow unit: lpm
  • Air changes per hour (optional): per hour

The room holds 2 × 2 × 2.5 = 10 m³ of air. Raising it by 1,500 − 420 = 1,080 ppm needs 10 × 1,080 ÷ 1,000,000 = 0.0108 m³ = 10.80 L (0.381 ft³) of CO₂, which weighs 0.0108 × 1.84 = 19.9 g. Releasing it over 10 minutes needs a flow rate of 10.80 ÷ 10 = 1.08 L/min, or 0.0648 m³/h = 2.29 ft³/h on a CFH regulator.

Sources & references

  • Greenhouse Carbon Dioxide Supplementation (HLA-6723)
    Oklahoma State University Extension · Retrieved 5 Nov 2026

    Ambient about 400 ppm, enrichment to 700–1,000+ ppm, damage at higher levels, compressed-tank regulators and flow meters, and 1 lb of CO₂ = 8.7 ft³ of gas (density ≈ 1.84 kg/m³).

  • NIOSH Pocket Guide to Chemical Hazards: Carbon dioxide
    U.S. National Institute for Occupational Safety and Health (CDC) · Retrieved 5 Nov 2026

    NIOSH REL and OSHA PEL TWA 5,000 ppm (9,000 mg/m³), NIOSH STEL 30,000 ppm, IDLH 40,000 ppm; symptoms of over-exposure.

Frequently asked questions

How much CO₂ do I need for a 70 cubic foot grow tent?
Multiply the volume by the ppm increase and divide by 1,000,000. From 420 to 1,200 ppm that is 70 × 780 ÷ 1,000,000 = 0.0546 ft³, about 1.55 L; going to 1,500 ppm needs 0.0756 ft³, about 2.14 L. Leaks and plant uptake mean you will need to top it up during the light period.
What CO₂ level should I aim for in a grow room?
Oklahoma State University Extension reports clear yield gains when C₃ crops are raised to roughly 700–1,000 ppm, and most growers enrich to 1,000–1,500 ppm. Above about 1,500–2,000 ppm there is little extra benefit and some crops show leaf damage. Enrichment only helps if light, water and nutrients are not limiting, and is pointless when the lights are off.
Is high CO₂ dangerous for people?
Yes. NIOSH and OSHA set an 8-hour time-weighted exposure limit of 5,000 ppm and a 15-minute NIOSH short-term limit of 30,000 ppm. Headache, dizziness and shortness of breath can appear before that. Ventilate the room or switch enrichment off before you work inside, and use a CO₂ monitor with an alarm.
How do I set a CO₂ regulator in CFH?
Divide the CO₂ volume in cubic feet by the release time in hours. If you need 0.381 ft³ in 10 minutes (1/6 hour), set 0.381 × 6 = 2.29 CFH. For a sealed room you then switch the valve off; for a leaky room add the make-up flow shown under leakage.
How many pounds of CO₂ will I use?
One pound of CO₂ is about 8.7 ft³ (246 L) of gas at room temperature. The 10.8 L in the example weighs about 0.044 lb, so a 20 lb tank holds roughly 450 such fills; leakage and repeated top-ups make real use much higher.

Related calculators

Daily Light Integral (DLI) Calculator Converts a grow light or sunlight reading into the daily light integral, the total number of photosynthetically active photons a square meter of canopy receives in one day. Enter the photosynthetic photon flux density (PPFD) from a quantum sensor in µmol/m²/s and how long the light is on, in hours, minutes or seconds, to get the DLI in mol/m²/day. Switch the mode to work backwards: find the PPFD a fixture must deliver to hit a target DLI, or how many hours a light must run to reach it. Potting Soil Calculator Works out how much potting soil fills your containers. Pick the container shape (rectangular planter or raised bed, round pot, or a tapered flower pot shaped like a truncated cone), enter its inside dimensions in inches, feet, millimetres, centimetres or metres, and set how many identical containers you have. You get the soil volume in US quarts, US dry quarts, US gallons, litres, cubic feet, cubic yards and cubic inches, plus how many bags of a given size to buy and how many pots one bag fills. Plant Spacing Calculator Plans how many plants a garden bed, orchard, vegetable plot or hedge will take. For an area, set the length, width and any unplanted border, then choose a square, rectangular (row) or triangular grid and either the distance between plants or a target number of plants per square metre or foot. For a hedge, enter its length, the spacing and one to four staggered rows, or the number of plants you want per row to get the spacing. Results include the plant count, rows and plants per row, the row spacing a triangular layout needs, planting density and, with a price per plant, the total cost.