Arrhenius Equation Calculator
Uses the Arrhenius equation k = A·e^(−Ea/RT) to work out how fast a reaction goes at a given temperature. By default it finds the rate constant k from the pre-exponential factor A, the activation energy Ea and the temperature, then shows how k changes nearby: the factor for a 10 °C rise, whether the familiar “rate doubles every 10 °C” rule holds, and k at temperatures around yours. It also predicts k at a second temperature from one measured value, finds the temperature that gives a target k, and solves for A or Ea. Ea can be entered per mole (kJ, J, kcal) or per molecule (eV, J), temperatures in °C, K or °F.
- A and Ea are treated as constant over the temperature range; real data often drift slightly, so predictions far from the measured range are less reliable.
- Activation energies entered must be zero or positive; temperatures must be above absolute zero.
Formula
- R = 8.314 J/(K·mol) and T is the absolute temperature in kelvin (°C + 273.15; (°F − 32) × 5/9 + 273.15). With Ea per molecule (eV or J), R is replaced by the Boltzmann constant k_B = 1.380649 × 10⁻²³ J/K; 1 eV = 1.602176634 × 10⁻¹⁹ J; 1 kcal = 4.184 kJ.
- Rearranged: A = k·e^(Ea/RT), Ea = R·T·ln(A/k) and T = Ea ÷ (R·ln(A/k)), which needs A > k. In log form ln k = ln A − (Ea/R)(1/T): a plot of ln k against 1/T is a straight line of slope −Ea/R.
- Second temperature: k₂ = k₁·e^((Ea/R)(1/T₁ − 1/T₂)). Temperature for a target k₂: 1/T₂ = 1/T₁ − R·ln(k₂/k₁)/Ea. A is not needed; it is shown as k₁·e^(Ea/RT₁).
- 10 °C factor (Q₁₀) = e^((Ea/R)(1/T − 1/(T + 10))). The Ea that makes it exactly 2 is R·ln 2 ÷ (1/T − 1/(T + 10)), about 53 kJ/mol at 25 °C and higher at higher temperatures.
- Rate constants and ratios are rounded to 4 significant figures (scientific notation below 0.001 or from 100,000 up), temperatures and Ea in kJ/mol or kcal/mol to 2 decimals, Ea/(RT) and logarithms to 4.
2NO₂ → 2NO + O₂ at 320 °C with Ea = 115 kJ/mol and A = 6.71 × 10⁹ M·s⁻¹
- Calculate: k
- Temperature unit: C
- Units of k and A: 0
- Pre-exponential factor (A): 6710000000
- Rate constant (k): 0.5
- Activation energy (Ea): 115
- Energy unit: kJ
- Temperature (T): 320
- Known rate constant (k₁): 0.5
- at temperature (T₁): 320
- New temperature (T₂): 330
- Target rate constant (k₂): 1
T = 320 + 273.15 = 593.15 K. Ea/(RT) = 115,000 ÷ (8.314 × 593.15) = 23.3197, so e^(−Ea/RT) = 7.454 × 10⁻¹¹ and k = 6.71 × 10⁹ × 7.454 × 10⁻¹¹ = 0.5001 M·s⁻¹, essentially 0.5 M·s⁻¹ (the small difference is because A was rounded to 3 figures). Warming to 330 °C multiplies k by e^(13,832 × (1/593.15 − 1/603.15)) = 1.472, so the rate does not double: at this temperature only an Ea of about 206 kJ/mol would double k every 10 °C.